Compressed air is essential for many industrial and commercial applications. However, it is important to remove condensate from compressed air systems to prevent damage to equipment and ensure efficient operation.
Condensate drains are devices that automatically remove condensate from compressed air systems. Level-controlled condensate drains are the most common type of condensate drain and offer several advantages over other types of drains, one example of these type of drains is ECO-DRAIN.
Condensate Problems in Compressed Air Systems
Condensate is water that condenses out of compressed air as it cools. Condensate can cause a number of problems in compressed air systems, including:
- Corrosion: Condensate can corrode metal components in compressed air systems.
- Freezing: Condensate can freeze in cold weather, causing damage to equipment.
- Reduced efficiency: Condensate can reduce the efficiency of compressed air systems by blocking airflow.
Function of Level-controlled condensate drain
See below drawing ( The condensate flows through the feed line 1 ( Supply line) into Level-controlled condensate drain unit and accumulates in the container 2. The capacitive sensor 3 continuously record the liquid level and passes a signal to the electronic control as soon as the container is filled. The pilot valve 4 is after that activated and the diaphragm 5 and automatically opens the outlet line 6 for discharging the condensate.
Level-controlled condensate drains are available in a variety of sizes and configurations to meet the needs of different compressed air systems.
Installation
Level-controlled condensate drains are typically installed at the lowest point in a compressed air system. The drain should be installed vertically, with the inlet at the bottom and the outlet at the top. The drain should be connected to a drain line that carries the condensate away from the compressed air system.
Proper Use
- The Level-controlled condensate drain is an electronically device for compressed-air plants. It's employed within the permissible operating parameters.
- The drain is able to drain condensate under operating pressure from the plant components virtually without compressed-air losses.
- As far as the employment in plants with increased demands on the compressed-air quality is concerned (food industry, medical technology, laboratory equipment, special processes, plants.. etc.), the operation department should decide according to the measures for the monitoring of the compressed-air quality.
- It is the task of the operator to ensure that the indicated conditions of the drain are met during the entire operating time.
- The Level-Controlled Condensate Drain and the condensate supply line need to be protected against frost, as otherwise the function cannot be guaranteed.
- It is important to size the condensate drain correctly for the compressed air system. A drain that is too small will not be able to remove condensate fast enough and will allow condensate to accumulate in the system. A drain that is too large will waste compressed air
Maintenance
Level-controlled condensate drains require regular maintenance to ensure proper operation. Maintenance tasks include:
- The condensate level should be checked regularly to ensure that the drain is operating properly. The condensate level can be checked by opening the sight glass on the drain.
- The housing and valve of the drain should be cleaned and checked regularly to remove any dirt or debris that may have accumulated. The drain can be cleaned by using a mild detergent and water.
- Replace the wearing parts of the drain regularly as per the instructions of the manufacturer's.
- The filter in the drain should be replaced regularly to ensure that the drain is removing condensate effectively. The filter can be replaced by following the manufacturer's instructions.
Troubleshooting
If a level-controlled condensate drain is not operating properly, there are a few possible causes:
- The condensate level is too high: The condensate level may be too high if the drain is not draining condensate fast enough. This can be caused by a number of factors, including a clogged drain line, a faulty drain valve, or a too-small drain.
- The condensate level is too low: The condensate level may be too low if the drain is draining condensate too frequently. This can be caused by a number of factors, including a leak in the drain line, a faulty drain valve, or a too-large drain.
- The drain is not draining condensate: The drain may not be draining condensate if the valve is stuck or the float is damaged.
If a level-controlled condensate drain is not operating properly, it is important to troubleshoot the problem and make repairs as necessary. By following the maintenance and troubleshooting of the manufacturer's, you can ensure that your level-controlled condensate drain is operating properly and helping to protect your compressed air system from damage.