DP Multivariable Mass Flow Transmitters

A DP (differential pressure) Multivariable Mass Flow Transmitter is a highly advanced flow measurement instrument that combines differential pressure, static pressure, and temperature sensing capabilities to accurately calculate mass flow rate, these transmitters are designed to measure the mass flow of liquids, gases, and steam in various industrial processes.


DP Multivariable Mass Flow Transmitters

In this post we will explore the working principle, operation procedures, maintenance procedures, calibration procedures, advantages, and disadvantages of DP Multivariable Mass Flow Transmitters.

Working Principle

DP multivariable mass flow transmitters are based on the principle of differential pressure, which is the pressure difference between two points in a fluid system, these transmitters typically consist of a primary device and a secondary device:

  • The primary device, also known as the flow-sensing element, is placed in the fluid flow path and causes a change in pressure due to the flow rate. 
  • The secondary device, which is connected to the primary device, measures this pressure change and converts it into an electrical signal.

The key component of the primary device is an orifice plate, which is a flat plate with a hole in the center. When the fluid flows through the orifice plate, it experiences a drop in pressure due to the restriction caused by the hole, the pressure drop is proportional to the flow rate of the fluid.

The secondary device, which is usually a differential pressure transmitter, measures this pressure drop and converts it into an electrical signal, which is then sent to a flow computer for further processing.


Operation Procedures

The operation of a DP multivariable mass flow transmitter involves a series of steps, as outlined below:

  1. The first step in setting up a DP multivariable mass flow transmitter is to install it in the fluid flow system, this involves mounting the primary device in the pipeline and connecting it to the secondary device via the impulse piping.
  2. Once the transmitter is installed, it needs to be configured to suit the specific application requirements, this includes setting the flow units, selecting the appropriate range scale, and calibrating the transmitter.
  3. Calibration is a critical step in the operation of a DP multivariable mass flow transmitter, this involves comparing the output of the transmitter to a known standard and adjusting it accordingly, calibration ensures that the transmitter provides accurate readings and improves its overall performance.
  4. After installation and calibration, the transmitter needs to be commissioned, which involves turning it on and verifying its readings against those of other instruments in the system, this step helps to confirm that the transmitter is functioning correctly and can be relied upon for accurate measurements.

Maintenance Procedures

To ensure the proper functioning and longevity of the DP multivariable mass flow transmitter, regular maintenance is essential, the following are some key maintenance procedures that should be carried out:

  • A visual inspection should be performed periodically to check for any signs of damage or wear and tear. Any indications of leaks, cracks, or corrosion should be addressed immediately.
  • A build-up of dirt or debris on the primary device or the impulse piping can affect the accuracy of the transmitter. Regular cleaning using a suitable solvent is recommended to maintain the transmitter's functionality.
  • With any precision instrument, re-calibration is necessary to ensure accurate readings, the frequency of re-calibration depends on the application and environmental conditions, but a general rule of thumb is to have the transmitter calibrated at least once a year.

Calibration Procedures

Calibration is a crucial aspect of the operation and maintenance of DP multivariable mass flow transmitters, here are the key steps involved in calibrating a DP multivariable mass flow transmitter:

  1. The reference standard used for calibration should have a known flow rate and a range that covers the expected process range, the flow rate can be measured using a gravimetric or volumetric method.
  2. The transmitter's output is compared to the reference standard's reading at different flow rates. Any discrepancies are noted and used to create a calibration curve.
  3. Based on the calibration curve, the transmitter is adjusted to match the reference standard's readings, this involves making changes to the electrical or mechanical components of the transmitter.
  4. The final step in the calibration process is to verify the accuracy of the transmitter by comparing its readings to those of the reference standard. Once the results are satisfactory, the calibration report should be recorded for future reference.

Advantages

DP multivariable mass flow transmitters offer several advantages over other flow measurement devices, including:

  • The ability to measure multiple variables such as temperature and pressure makes these transmitters suitable for a wide range of fluid applications.
  • With proper calibration, DP multivariable mass flow transmitters can offer high accuracy levels, making them ideal for critical applications.
  • These transmitters provide real-time measurements, allowing for prompt action in case of any process variations.

Disadvantages

There are a few drawbacks to using DP multivariable mass flow transmitters, such as:

  • The installation of a DP multivariable mass flow transmitter can be more involved than other flow meters, as it requires impulse piping and proper alignment of the primary device.
  • Extreme temperatures, high pressures, and corrosive fluids can affect the accuracy and lifespan of DP multivariable mass flow transmitters.

In short, DP multivariable mass flow transmitters working principle, operation, and maintenance procedures should be understood and followed correctly to ensure their proper functioning, it's crucial to consider the limitations that may affect their performance in specific applications, with regular calibration and maintenance, these transmitters can provide reliable and accurate flow readings for many years.